VENTS TT Silent - M 200

  • 9,947грн
  • Availability:Check availability
  • Brand: Vents

Tags: VENTS, TT Silent - M 200, ventilation

Air consumption 804 m3/h

Fan power, W 0.11 kW

Pipe diameter 199 mm

Power Options 1/230/50

Noise level 49 dBA

Fan speed 2116 rpm

Fan current 0.9 A

Maximum air consumption, m3/hour 804

Length height width 295.5/261/239 mm


The duct fan from Vents TT 200 series is based on the best technologies that have been obtained in the study of not only duct, but also centrifugal, axial type of ventilation equipment. Therefore, this series of instruments is powerful, easy to operate and equipped with additional functions to increase efficiency. Laconic design and small size will only be a plus.

Application

A fan of this model can be used in various buildings and areas: shops, offices and offices, apartments, utility rooms, private houses, and restaurants with high pressure in the ventilation ducts. After all, they carry out a powerful process of work, but at the same time they work quietly. Such a fan is suitable even for rooms with high humidity. The devices of this series are suitable for installation with round ducts, with a wide range of diameters - from 100 to 315 mm.

Design

What else is needed for the long-term operation of the ventilation device? Of course, durable construction and protective properties. Just this model has such properties. Case: one of the most important elements of the device is made of a special light but strong ABS plastic, which is protected from UV rays. For special savings, the case was covered with polypropylene inside, which will secure the mechanism in fire hazardous rooms. What distinguishes the model from axial types is the impeller - it is made in a conical shape with directional blades. Such an impeller, together with a diffuser, increases the pressure inside, which positively affects the performance and efficiency of air circulation. A special feature is that in this design, even at maximum power, the fan emits a minimum of noise and vibration. And in order to increase the feeling of comfort and regulate the smooth and gradual flow of air masses into the mechanism, the design is equipped with an inlet pipe with a collector.

Engine

It is designed for single-phase power supply, and rests on rolling bearings. On the plus side, you can get a kit with a beefed-up motor, as well as pick up a model with one or two speeds. To protect the mechanism, the motor has a thermal fuse that is connected to the winding. The advantage will be that even if you select a model with increased engine performance, it will still be economically powered by energy.


Peculiarities

This series has different performance features. For example, as a functional "U" and "U1" - such a unit is equipped with a temperature sensor built into the body, an electronic thermostat with a reaction light indicator, as well as a speed controller and a delay timer, which also works together with the sensor and does not allow changing the speed fan at high temperature. The functions "Un" and "U1n" have the same equipment, only all the above elements are placed 4 m on a fixed cable. There is also another difference - the “U” and “Un” models work on the principle of triggering a temperature sensor, which does not make it possible to change the speed, but the “U1” and “U1n” units do not allow switching the mode when the timer is set, say 5 minutes.

Instrument modifications

C - the model is equipped with an engine that has increased power

T - built-in timer to delay the shutdown of work (from 2 to 30 minutes)

R - has an additional power cable with an IEC C14 electrical connector

B - a speed switch with three positions is attached to the body of the device

Control

Unfortunately, only two-speed models can regulate the air flow. The latter can have different control paths: using the built-in switch, if you have chosen a model with modification "B", or separately order the RS-1-300 speed controller. The "P" option will allow you to smoothly switch speeds.

Mounting

Such a fan is installed in the air duct anywhere in the ventilation system at a convenient angle. It is possible to fix several fans in the channels. Central vent. The unit is mounted using latches and clamps, which makes it easy to maintain the device. If you want to attach the device to the wall, a flat mounting plate is used for this purpose. In this case, the mounting box is mounted in any position. If you need to service the mechanism or clean all the elements, then you only need to pull out the central unit, but the entire fan remains attached - this is convenient and fast. Also during installation, you can increase productivity by placing a pair of models in parallel, or in series one after the other to increase pressure.

Write a review

Write a review
Note: HTML is not translated!
    Bad           Good

If you have any questions, write to us:

We do not advise on the cultivation and germination of our souvenirs, if you are interested in this information, you can easily find it on the Internet